Note: Users must have a Formula for their RTD already built in Dx5 before attempting this process. A how-to guide on building RTD Formulas in Dx5 can be reviewed here: Setup: Create New RTD Formula (Read Time: 4 mins).
From Operations > Overview, locate the Batch active in Bulk Processing and click the underlined Batch Type name to enter the Batch Details page.
From the Batch Details page:
- Navigate to Batch Actions > Add Materials
- From the Add Option menu, select "Run Formula" and choose the applicable Formula from the drop-down menu.
- On the Run Formula form, enter a Run Date/Time to reflect when this Formula was applied.
- Confirm the Formula Materials and Material Amounts displayed below:
- If a Dx5 Formula is set to Scale and is being applied to a Processing Batch Volume which is different from the Baseline Batch Volume on the Formula, observe Scaling. Dx5 will present a system message indicating the following materials have been adjusted to the current batch size (% Scale of Baseline Batch Volume).
- If a Dx5 Formula is applied to the exact Baseline Batch Volume, confirm Materials and Material Amounts.
- If a Material Amount needs to be edited further, click into the Unit field and overwrite the Formula's value with your own.
- If Batch Type Modifier is applied, users will see a message asking them to confirm the Batch Type edit running the Formula will make.
- The Formula's Batch Type Modifier should be set up in a way which won't require further edits, but if users do need to revise the Starting or Ending Batch Types they can via the drop-down menus available for each.
- Confirm the Formula Materials and Material Amounts displayed below:
- Click Run Recipe to apply the Formula, or Cancel Formula if you don't wish to run it at this time.
Once a Formula has been successfully ran, users can view the application in their Batch History tables on the Batch Details page.
Note: Users will also notice Volume/Alcohol Content changes in line with the established Formula. Volume added as a result of a Dx5 Formula application should include all liquid Formula Materials as well as water required to reduce the Batch to the Formula's End ABV.
If the new Dx5 Batch Volume differs from a gauged result on-site, simply Recalibrate the batch via Batch Actions > Recalibrate to provide Dx5 with the accurate gauged Volume. A resource on Recalibrating can be viewed here: Operations: Recalibrate Batch (Read Time: 2 mins).
Comments
0 comments
Please sign in to leave a comment.